A roof valley that leaks in wind-driven rain, re-slated with fibre cement slates and still leaking after three roofers have had a go, usually comes down to how the valley was built rather than the slates themselves. That’s Roger’s view on Paul’s roof, and before you replace a whole slate roof it’s worth checking the same details on yours.
Paul’s 1920s house was re-slated about 20 years ago. Around two years later the valley started leaking, always in the same place and always when the rain is blown in by the wind. The first roofer took it apart, couldn’t find the problem, put it back, then left scaffolding up for a year before walking away. The second stripped the valley out, charged about £800 and thought he’d fixed it. He hadn’t. All told, Paul has spent around £12,000 and he’s back where he started.
Working from Paul’s photos of the stripped roof, Roger goes through what he can see and what he’d do, then asks the roofers watching for their view.
The trouble with fibre cement slates
Roger isn’t a fan of man-made fibre cement slates. They’re relatively weak, so if the wind gets under one it can snap, which is why every slate has to be held down at the tail with a rivet and a turned-down metal tag. At first glance Roger thought they’d been left out on this roof, but looking closer, they’re there.
The bigger issue is how flat and uniform they are. Natural riven slate varies in thickness and has an undulating face, so there’s always a bit of air moving underneath. Fibre cement slates sit so tight together that, if anything, they draw moisture up between them by capillary action, and it sits under the slate with nowhere to go.
Breather membranes and counter battens
Under the slates, the roofer has used two breather membranes: Tyvek from DuPont on one side and Cromar Vent 3 on the other. Both are good products. Vent 3 has three layers that let moisture evaporate through while the top layer sheds water, and the claim is that you don’t need separate loft ventilation with it because the membrane itself is air open.
What Roger says the manufacturers also ask for is counter battens. These run up the rafters first, with the slate battens fixed across the top. Moisture escaping from the house comes through the membrane, hits the cold underside of the slates and condenses. Without counter battens, those droplets are trapped behind the battens with nowhere to drain. With them, there’s a clear channel for the water to run all the way down the roof, and an up and over counter batten system lets air move over the ridge and down the other side as well.
Counter battens don’t have to be expensive or thick. An 11mm strip is enough, it barely raises the roof height at the fascia, and good roofing merchants stock it. Roger reckons most UK roofers simply don’t like using it, but with fibre cement slates he considers it essential. On this roof there aren’t any.
Membranes stretched drum tight make it worse. The moisture coming through a roof can be litres a day, and if it sits trapped behind the battens, all it takes is a small hole in the membrane for it to find its way in.
Why this roof valley leaks
Even so, Roger doesn’t think the missing counter battens explain a leak that only appears in wind-driven rain. The valley does.
A valley needs a tilting fillet down each side, which is a strip of timber or similar that raises the edge so wind-driven rain can’t run up under the slates. Whatever lines the valley, whether lead, zinc, GRP or one of the lead substitutes, it dresses up and over that fillet. For that to work, the slates need to sail over the top of the valley and be cut in, which means the battens have to sit slightly higher than the valley lining.
On Paul’s roof the battens run straight into the valley. Put a tilting fillet in, or a moulded GRP valley, and it would sit higher than the slates, leaving them cocked up along both edges. Roger suspects whoever did it just folded a welt into the edges of a lead or zinc lining and hoped that would keep the rain out. None of the three roofers mentioned the missing counter battens or the batten height.
The batten ends haven’t been cut to the angle of the valley either, so some don’t even sit on a rafter. You can also see staining where dirt and water have run down the roof over the years. In Roger’s words, the whole thing is a dog’s breakfast.
What Roger would do
Before any slates go back on, run a hose over the stripped valley and watch where the water gets through. It may turn out to be one piece of membrane that can be replaced on its own. The membrane also wants taping down where it’s lifting.
Re-battening the whole roof with counter battens to get the height right would be a crazy amount of work. Instead, Roger’s suggestion is to take the valley out and set it lower, down into the rafters, then run the battens over the top of it. A GRP valley would then overlap the battens on both sides, and the slates would still run through at the right height. He’s done it before, and it’s a fair bit of work, but it puts the problem right instead of patching it again.
The lead work round the chimney, with its soakers under the slates, looks like it’s doing its job, and the 1920s engineering brick chimney is still going strong.
Key takeaways
- Fibre cement slates are smooth and uniform, so they sit tight together and can draw moisture up between them by capillary action, where natural riven slate leaves room for air to move underneath.
- Counter battens are worth fitting with fibre cement slates and a breather membrane, because they give condensation coming through the membrane a clear channel to run down the roof instead of sitting trapped behind the battens.
- A valley needs a tilting fillet or a welted edge on both sides to stop wind driven rain getting under the slates, and that only works if the battens sit slightly higher than the valley lining.
- On this roof the battens run straight into the valley without being cut to the angle, so some don’t even reach a rafter, and fitting a fillet or GRP valley would leave the slates cocked up along the edge.
- Before the slates go back on, running a hose over the stripped valley should show where water is getting through the membrane, and a small patch repair may be all it needs.
- Roger’s suggested fix is to take the valley out, set it lower into the rafters and run the battens over it, so a GRP valley overlaps the battens on both sides and the slates still run through at the right height.
Frequently asked questions
Do fibre cement slates need counter battens?
Roger considers them essential with fibre cement slates and a breather membrane, because they let condensation drain down the roof instead of being trapped behind the battens. A thin 11mm counter batten is enough.
Why does a roof valley only leak in wind-driven rain?
Usually because there’s nothing stopping the rain being blown sideways under the slates. A tilting fillet or welted edge on each side of the valley stops that, provided the battens sit higher than the valley lining.
What is a tilting fillet?
A strip of timber or similar that runs down each edge of a valley and lifts the edge of the lining, so water blown across the roof can’t run up and under the slates.
WATCH NEXT
- Why Roofers Are Switching to This New Slate System
- 4 Roofers Couldn’t Solve This Damp Chimney. Can You?